MODEL FDTC50VD
Type Compact Cassette Type
Nominal Cool/Heat Capacity (ISO T1/H1) kW 5.0/5.8
Dimensions mm Unit: 248 x 570 x 570 Panel: 35 x 700 x 700
Weight kg 15
Sound Pressure Level Cool/Heat Hi Fan dB(A) 42/42
Airflow Cool/Heat Hi Fan l/s 192/191
Refrigerant Piping mm 6.35/12.7 ø

Functions Glossary

Filter

Allergen Clear Filter

The filter break down the pollen, lice, and all allergens that live on cat skins, etc. and deactivates them.

Photocatalytic Washable Deodorizing Filter

It keeps air fresh by deodorizing the molecules causing odor. The deodorizing ability can be easily restored simply by cleaning and exposing to the sunlight.

Natural Enzyme Filter

Enzymes used in the filter are naturally occurring lytic enzymes which attack cell walls of microorganisms trapped on the filter and destroy them.

Allergen Clear System

The 'Allergen Clear system' suppresses the infl uence of the allergen caught by the filter by controlling the temperature and humidity.

Self Clean Operation

The 'self clean operation' is operated for 2 hours after the unit has ceased normal operation. The indoor fan continues to operate on ultra low speed to dry the unit. This restricts the growth of mould. This feature can be selected on the remote control.

Comfortable Functions

Fuzzy Auto Mode

Automatically the unit determines its operating mode and temperature and setting based on a fuzzy calculation and adjusts the inverter frequency.

Automatic Operation

The air-conditioner automatically selects from heating, cooling or dry operation.

Hi Power Operation

The unit can operate continously in HI POWER mode for 15 minutes. This mode is used to reach the desired temperature quickly.

Three "Hot" System

'Hot start' enables the unit to begin heating operation quickly.
'Hot spurt' a fast heating system that works to increase the temperature setting by two degrees.
'Hot keep' used during the automatic defrost cycle to prevent cool air being circulated.
These three operational control systems help ensure comfortable and efficient heating.

Comfortable Air Flow Functions

3D Auto

You can choose the best heating or cooling pattern with the touch of a button.

Auto Flap Mode

The unit automatically selects the optimal angle whatever the operation mode.

Air Scroll

The swing of the flap causes the air flow to spiral and the breeze reach all corners of the room.

Memory Flap

While the flap is swinging it can be stopped at any angle. The flap returns to this position next time the unit starts operation.

Up/Down Flap Swing

The Up/Down flap can be adjusted to the preferred angle anywhere between horizontal and perpendicular.

Lateral Swing

The louver swings from right to left automatically. Louver angle can be fixed in any desired position.

Air Outlet Selection

Both lower and upper air outlets and upper air outlet can be selected. (SRF models only)

Positioning of Installation

You can set the leftright air fow directions when you installed the air conditioner near the side wall by remote controller operation.

Convenience and Economy Functions

Economy Mode

The unit achieves effective energy saving operation while still keeping a comfortable cooling or heating operation.

On Timer

This enables the operation to start a little earlier so that the room is near to set temperature at ON time.

Dry Operation

The unit dehumidifies the room by intermittent cooling operation.

24-hour On/Off Programmable Timer

By combining a start timer with a stop timer you can register two timer operations a day. Once set timers will start or stop the system at the specified time of the day repeatedly.

Off Timer

The unit stops at the specified time.

Sleep Mode

The room temperature is automatically controlled during that set sleep mode period ensuring that the room temperature will not get too hot or cold.

Maintenance and Prevention Functions

Microcomputer Operated Defrosting

This function automatically eliminates frost and helps minimize excessive operation in other modes.

Self Diagnostic Function

If the air-conditioner malfunctions an internal microcomputer runs a self diagnosis. Inspection and repair should be performed by authorized dealers.

Detachable Indoor Air Panel

The air inlet panel on the indoor unit opens and closes easily making filter cleaning simple. The suction panel can be easily removed.

When removing the air inlet panel for internal cleaning or other reason, open the grill by 65 degrees and then pull it to the side.

Other Functions

Back-up Switch

On the indoor unit there is a back up on/off switch. The system will operate in the previous mode.

Auto Restart Function

Power blackout auto restart function records the operational status of the air-conditioner immediately prior to being switched off by power supply interruption. The unit automatically resumes operations in that mode and temperature set point after the power has been restored. .

24-hour ION

The air-conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated when the air-conditioner is not running, allowing you to experience them without incurring any electrical cost.

Luminas Button

The wireless 'Luminas' remote control that glow in the dark. It is possible to operate all desired functions of the unit with a touch of a button.